Volume : 6, Issue : 11, November - 2017

Effect of splinting in fixed partial denture- A 3D Finite Element Analysis

Dr Mehul R Mahesh, Dr Bennett Atlin Correya, Dr Joy Pt

Abstract :

<p>&nbsp;<span lang="EN-IN" style="font-size: 12pt; line-height: 115%; font-family: &quot;Times New Roman&quot;, serif; color: rgb(34, 34, 34); background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;">Fixed Partial dentures often require splinting of multiple abutments to overcome mechanical problems of &nbsp;long edentulous span or&nbsp; loss of bone support of &nbsp;abutments.</span><span lang="EN-IN" style="font-size:12.0pt;line-height:115%;font-family:&quot;Times New Roman&quot;,&quot;serif&quot;;&#10;mso-fareast-font-family:&quot;Times New Roman&quot;;mso-fareast-theme-font:minor-fareast;&#10;color:#222222;mso-ansi-language:EN-IN;mso-fareast-language:EN-IN;mso-bidi-language:&#10;AR-SA">< /> <span style="background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;">The study &nbsp;analysed stress levels in teeth and supporting structures in fixed prosthesis by Finite element method to assess &nbsp;how&nbsp; multiple abutments in fixed prosthesis modifies the stresses and deflections.&nbsp;</span>< /> <span style="background-image: initial; background-position: initial; background-size: initial; background-repeat: initial; background-attachment: initial; background-origin: initial; background-clip: initial;">The stress and deflection was reduced &nbsp;in the supporting structures when a fixed prosthesis was faicated and teeth were splinted together as 4, 5 or 6 unit FPD however by increasing the abutments the reduction of stress on the periodontium was not proportional. Stress concentrations were observed in the connector area and cervical tooth area adjacent the edentulous ridge.&nbsp; It was concluded that the mechanical problems of a long span FPD can not be completely managed by increasing the number of abutments.&nbsp;</span>< /> <!--[if !supportLineBreakNewLine]-->< /> <!--[endif]--></span></p>

Keywords :


Cite This Article:

Dr Mehul R Mahesh, Dr Bennett Atlin Correya, Effect of splinting in fixed partial denture- A 3D Finite Element Analysis, GLOBAL JOURNAL FOR RESEARCH ANALYSIS : VOLUME-6, ISSUE-11, NOVEMBER-2017


Article No. : 1


Number of Downloads : 1


References :